Foundation types and what decides them
As at · 17 sources
Ultimate Foundations ·
The short answer
The ground decides first, then the house, then the engineer. In Canterbury the of the land and the bearing capacity the investigation finds set which family of foundation can go in; the shape of the house and the weight of its cladding and roof narrow it down; and the engineer's design settles it. A foundation type is chosen for the site, not from a brochure.
Key points
- MBIE's guidance says TC1 is generally regarded as the category most likely to be good ground. It says TC2 and TC3 fall outside the definition of good ground for standard residential construction, so their foundations are not within the scope of NZS 3604.1
- On TC2 land, MBIE's guidance uses NZS 3604 timber piles or an enhanced perimeter foundation wall where the ground is above 300 kPa, the enhanced slab Options 1 to 4 or other specific design where it is above 200 kPa, and specific design below that.2
- For new houses on TC3 land, MBIE's guidance offers three broad foundation families: deep piles, site ground improvement, and surface structures with shallow foundations.3
- Type 2A and Type 2B are TC3 surface structures in MBIE's Canterbury residential guidance. They are not TC2 foundations.4
What decides which foundation goes on a section?
Three things, in this order: the ground, the house and the engineer. The technical category and the bearing capacity the investigation finds set which foundations MBIE's guidance allows. The weight of the wall and roof cladding and the shape of the plan narrow the choice. The engineer's design makes the final call, and the council checks it.
On TC1 land, MBIE's guidance accepts NZS 3604 timber piles or tied NZS 3604 concrete slabs where a shallow investigation shows an ultimate bearing capacity above 300 kPa; between 200 and 300 kPa it points to the TC2 slab options or other specific design, and below 200 kPa, or where there is peat, to specific design.5On TC2 land the same test runs against MBIE's own list, shown in the key points above: a timber floor on NZS 3604 piles, or on an enhanced perimeter foundation wall, needs the firmest ground; the enhanced slab options accept ground that bears less; and below that, the foundation is . The slab options are drawn up with a structural engineer overseeing them:
MBIE's guidance says the TC2 slab Options 1 to 4 are not expected to need specific engineering design, but structural engineers must oversee their documentation; they apply to simple plan shapes and carry limits on wall and roof cladding weight.6On TC3 land every foundation is specifically engineered. What the categories mean, and how to find the one for an address, is in Technical categories: TC1, TC2 and TC3 in plain English.
What are MBIE's house types A, B and C?
They are MBIE's names for the three ways a house on the flat meets the ground: is a timber floor on piles, a timber floor with a concrete perimeter foundation, and a concrete slab on the ground. They describe the floor and its foundation, not the land.
MBIE's Canterbury guidance groups houses on the flat as Type A, a timber floor on piles only; Type B, a timber floor with a perimeter concrete foundation; and Type C, a concrete slab-on-grade. Types B and C are split by cladding: B1 and C1 for light or medium cladding such as weatherboard, and B2 and C2 for heavy cladding such as brick or concrete masonry veneer.7What is a pod raft foundation?
A pod raft is a concrete slab poured over polystyrene pods, with concrete ribs between them. It is a type of foundation, not a brand: you may have heard it called RibRaft, which is Firth's brand name, and Allied's SuperSlab and MBSS's MAXRaft are competing versions of the same type. On TC2 land, MBIE's own slab options include pods, as the next answer shows.
How one goes in, and what the engineer decides, is in Pod raft foundations.
What are the TC2 slab options in MBIE's guidance?
MBIE's guidance numbers four enhanced slabs for TC2 land, Options 1 to 4. They are designed to cope with some settlement of the ground beneath them without specific engineering design, but an engineer still oversees the documentation, and they are limited to simple plan shapes and to set cladding weights. Anything outside those limits is designed specifically.
The four TC2 options in MBIE's guidance are Option 1, a reinforced NZS 3604 slab on a compacted gravel raft; Option 2, a thick slab over the existing soil; Option 3, a grid of beams with a slab, where the hardfill under the slab can be replaced with polystyrene pods; and Option 4, a waffle slab over the existing soil.8Each option needs ground that passes MBIE's bearing test:
MBIE's guidance treats 300 kPa, for NZS 3604 foundations, and 200 kPa, for the TC2 slab options, as index values of ultimate bearing capacity, checked with a Scala penetrometer.9What foundations are used on TC3 land?
Specifically engineered ones, chosen after a deep investigation. MBIE's guidance describes three families: deep piles taken down to a dense layer that will not liquefy, improving the ground so a TC2-type slab can be used, and that sit on top of the ground and can be relevelled if it settles.
MBIE's guidance says deep pile foundations always need specific engineering design.10 On TC3 land, site ground improvement aims to improve the ground so one of the TC2 slab options can be used, and MBIE's guidance says ground improvement that forms part of the foundation needs a building consent, and may need a resource consent as well.11 MBIE describes surface structures as shallow-founded options that can be used on most TC3 sites without ground improvement or deep piles, and can be relevelled after future settlement; they are only for timber- or steel-framed houses with light roofs, light or medium wall cladding and regular plans.12Are Type 2A and Type 2B the same thing as TC2?
No. and are surface structures for TC3 land in MBIE's guidance. The 2 in their names numbers a family of surface structures, not a technical category, and MBIE's own summary table keeps them apart from the TC2 slabs, which it numbers as Options.
In MBIE's guidance, Type 2A and Type 2B are a timber floor on short timber piles that sit on a reinforced concrete underslab rather than in the ground: the underslab is 150 mm thick on a gravel raft for Type 2A, and 300 mm thick for Type 2B.13 MBIE's own summary table lists the TC2 concrete rafts as Options 1 to 4 and the TC3 surface structures as Type 1, Type 2 and Type 3, side by side with the house Types A, B and C.14If a page or a quote describes one of these as a TC2 foundation, ask which MBIE option it actually means.
Is there a standard for screw piles?
No New Zealand standard covers screw pile design. The piles NZS 3604 deals with are timber or concrete, and the timber ones have a standard of their own; neither of them is a screw pile.
That does not make a screw pile unusual, or unapproved. It means each one is proven on its own, by one of two routes: a specific engineering design for that job, or a product certificate for that particular pile, used within the conditions the certificate sets. Certificates for screw piles do exist on the register.
So the question worth asking of a quote that includes them is which of the two it rests on, because they are different kinds of assurance and they are checked in different ways.
What does good ground mean in Canterbury?
Good ground is a term from NZS 3604: the standard defines it, and your engineer applies it. What matters in Canterbury is what MBIE's guidance says about it. MBIE says TC1 land is generally regarded as most likely to be good ground and puts TC2 and TC3 land outside it, as the key points above quote. It also says what should happen where good ground cannot be confirmed, and it counts any peat against it:
MBIE's guidance says that where good ground cannot be confirmed, the NZS 3604 concrete floor and foundation provisions should not be used without specific engineering design input, and that in many areas of greater Christchurch the good-ground provisions may not apply.15 In Canterbury, MBIE's guidance changes the NZS 3604 list of ground that does not count as good ground so that it names peat of any kind, not only soft or very soft peat, so any peat takes a site outside it.16Whether a section's ground qualifies is a question for the investigation, not the map:
On TC1 and TC2 land, MBIE's guidance expects a shallow investigation of the ground, with hand auger boreholes and a Scala penetrometer, to establish its bearing capacity; on TC2 land it says that work needs to be done under the guidance of a CPEng qualified engineer.17Who to contact
- A geotechnical engineer
- What the ground under your section is, and what it will carry. They investigate it and write the report the foundation is designed from.
- The engineer who designs your foundation
- What goes under the house, and why. Thickness, steel, beams and the system itself are settled here.
- Your council
- Whether the work needs a building consent, what has to be shown, and when it is inspected.
- The Licensed Building Practitioners register
- Whether the person doing restricted building work holds a licence for it. It is a free public search and it takes a minute.
- Us
- What we would build, what it would cost, and what we would need from you before we could start.
If you are told something is not possible, it is always worth asking which of these decided it. The ground and the Code are fixed. A design and a programme sometimes are not.
What we do here
Tell us the address, and send the geotechnical report if there is one. We will tell you what the ground points to, what your engineer settles, and which parts of the job are ours.
Sources
MBIE's Canterbury guidance, Parts A and C, is published on building.govt.nz.
See also the technical category entry in the glossary.
- MBIE, Repairing and rebuilding houses affected by the Canterbury earthquakes, Part A, Version 3 (December 2012), section 3.1. Checked . Read the source
- MBIE, Repairing and rebuilding houses affected by the Canterbury earthquakes, Part A, Version 3 (December 2012), Table 5.2. Checked . Read the source
- MBIE, Repairing and rebuilding houses affected by the Canterbury earthquakes, Part C, Version 3a (April 2015), section 15.1.1 and Table 15.1. Checked . Read the source
- MBIE, Repairing and rebuilding houses affected by the Canterbury earthquakes, Part C, Version 3a (April 2015), section 15.4.4. Checked . Read the source
- MBIE, Repairing and rebuilding houses affected by the Canterbury earthquakes, Part A, Version 3 (December 2012), Tables 5.1 and 5.2. Checked . Read the source
- MBIE, Repairing and rebuilding houses affected by the Canterbury earthquakes, Part A, Version 3 (December 2012), sections 5.2 and 5.3. Checked . Read the source
- MBIE, Repairing and rebuilding houses affected by the Canterbury earthquakes, Part A, Version 3 (December 2012), section 2.1 and Table 2.1. Checked . Read the source
- MBIE, Repairing and rebuilding houses affected by the Canterbury earthquakes, Part A, Version 3 (December 2012), section 5.3.1. Checked . Read the source
- MBIE, Repairing and rebuilding houses affected by the Canterbury earthquakes, Part A, Version 3 (December 2012), section 3.4.1. Checked . Read the source
- MBIE, Repairing and rebuilding houses affected by the Canterbury earthquakes, Part C, Version 3a (April 2015), section 15.2. Checked . Read the source
- MBIE, Repairing and rebuilding houses affected by the Canterbury earthquakes, Part C, Version 3a (April 2015), June 2015 update to section 15.3. Checked . Read the source
- MBIE, Repairing and rebuilding houses affected by the Canterbury earthquakes, Part C, Version 3a (April 2015), section 15.4.1. Checked . Read the source
- MBIE, Repairing and rebuilding houses affected by the Canterbury earthquakes, Part C, Version 3a (April 2015), section 15.4.4. Checked . Read the source
- MBIE, Repairing and rebuilding houses affected by the Canterbury earthquakes, Part A, Version 3 (December 2012), Table 7.2. Checked . Read the source
- MBIE, Repairing and rebuilding houses affected by the Canterbury earthquakes, Part A, Version 3 (December 2012), section 5.2. Checked . Read the source
- MBIE, Repairing and rebuilding houses affected by the Canterbury earthquakes, Part A, Version 3 (December 2012), section 3.4.1. Checked . Read the source
- MBIE, Repairing and rebuilding houses affected by the Canterbury earthquakes, Part A, Version 3 (December 2012), section 3.4.1 and Table 5.2. Checked . Read the source