Pod raft foundations

As at · 6 sources

A pod raft is a concrete slab poured over polystyrene pods, with concrete ribs between them.

One reinforced floor

Steel runs through the ribs and the slab, and the whole thing works as one reinforced floor sitting on the ground.

You may know it as RibRaft, which is Firth's brand name. Firth's RibRaft, Allied's SuperSlab and MBSS's MAXRaft are competing versions of the same type. The engineer's plans say which one goes on a site.

Close along an edge beam, steel tied over white pods, edge insulation inside the boxing and a yellow cap on a starter bar

The engineer designs it for your ground

Everything structural is the engineer's: the rib layout, the edge beams, the steel, the slab thickness, and whether a pod raft suits the ground at all.

On land, MBIE's slab options are drawn up with a structural engineer overseeing them:

MBIE's guidance says the TC2 slab Options 1 to 4 are not expected to need specific engineering design, but structural engineers must oversee their documentation; they apply to simple plan shapes and carry limits on wall and roof cladding weight.1

Pod raft systems carry either a CodeMark certificate or a BRANZ Appraisal, and each one sets out the scope its standard details cover.2 A certificate covers the product, used within its conditions, and the engineer's design covers your site.

A boxed building platform covered in white insulation pods laid in a grid, houses and hills beyond

On TC3 land

A pod raft goes on TC3 land only as part of a . The geotechnical and structural engineers choose the route, and one of their routes improves the ground first:

On TC3 land, site ground improvement aims to improve the ground so one of the TC2 slab options can be used, and MBIE's guidance says ground improvement that forms part of the foundation needs a building consent, and may need a resource consent as well.3

How it goes in

The building platform is cleared and levelled to the heights on the plans, and the edges are boxed. The goes down, then the pods on their spacers, then the steel in the ribs and edge beams and the mesh over the pods. The plumber and the electrician set their pipes and ducts where the plans put them.

A cut through the edge of a pod raft floor before the pour, with the building platform at the bottom, a membrane over it dipping down under the thicker edge beam, polystyrene pods on small spacers with concrete ribs between them, steel in the ribs and in the edge beam, and a mesh running across above the pods.

Nothing is poured until the council has inspected

In Christchurch, the inspection before the pour is the council's Foundation or Slab inspection:

Christchurch City Council's inspection called Foundation or Slab happens before the concrete is poured. For a slab on the ground the inspector checks, among other things, that the damp-proof membrane is lapped and taped, the reinforcing is placed and tied, the mesh is supported on chairs, and shrinkage control joints are formed; the council says these are minimum requirements, and if any is not met the inspection fails.4

Then the slab is poured and left to cure.

A boom pump pouring concrete over steel and orange underfloor heating pipe, the crew working across the floor

What moves the price

The price comes from your plans and your site. These move it:

  • The ground, and the investigation behind the design. The ground category sets how deep the investigation goes: MBIE's guidance expects a shallow investigation for a new house on TC1 or TC2 land, and on TC3 land a site-specific deep investigation with geotechnical analysis.5
  • The outline of the house. Edge beams run the whole perimeter, so a long or complicated outline means more of them.
  • The loads on the slab. Heavy cladding such as brick veneer, or a second storey, changes the steel and the beams the engineer specifies.
  • The site. How machinery and concrete trucks get in, and how much earthwork the platform needs.
  • What goes into the slab. Services, set-downs for showers, garage doors or brick veneer, and insulation where the drawings call for it.

Does a pod raft need insulation?

Your designer decides that when showing how the house meets H1, the energy-efficiency clause of the Building Code. Any insulation is shown on the consented drawings. Under H1/AS1, the slab counts in that calculation whether it is insulated or not:

Under the 6th edition a slab still has a construction R-value in the house's heat-loss calculation, taken from the Appendix E tables or from H1/VM1; the slab's area-to-perimeter ratio drives the result, and where edge insulation covers only part of the perimeter the value is pro-rated.6
Two crew members fitting edge insulation along the boxing, a site radio beside them

What we need from you

To price a pod raft we need:

  • the plans, and the engineer's foundation design if there is one yet;
  • the geotechnical report for the section;
  • the site address, and anything we should know about getting onto the site;
  • who the builder is, if you have one.

What we do here

UF builds pod raft foundations for TC1 and TC2 sites, and engineered foundations for TC3 sites, using Firth RibRaft, Allied SuperSlab or MAXRaft depending on what the engineer's plans specify.

Send the plans. We will tell you what your section allows, what the engineer settles before anyone can price it, and what we need to price the work.

Sources

  1. MBIE, Repairing and rebuilding houses affected by the Canterbury earthquakes, Part A, Version 3 (December 2012), sections 5.2 and 5.3. Checked . Read the source
  2. MBIE Building CodeHub, register entries for pod raft floor systems. Checked .Source: Ministry of Business, Innovation and Employment, Building CodeHub (codehub.building.govt.nz), licensed under CC BY 4.0; restated in part. Licence terms
  3. MBIE, Repairing and rebuilding houses affected by the Canterbury earthquakes, Part C, Version 3a (April 2015), June 2015 update to section 15.3. Checked . Read the source
  4. Christchurch City Council, Guide to Building Inspections (B-306), version 10 (last updated 15 June 2026), pages 7 and 8, Foundation or Slab. Checked .
  5. MBIE, Repairing and rebuilding houses affected by the Canterbury earthquakes, Part A, Version 3 (December 2012), Table 5.2. Checked . Read the source
  6. MBIE, H1 Energy efficiency, Acceptable Solution H1/AS1, 6th edition, paragraphs 2.1.3.1 c), E.1.1.1, E.1.2.2 and E.1.2.3. Checked . Read the source
Technical category (TC1, TC2, TC3)The categories of residential land on the flat in greater Christchurch, TC1 to TC3, as MBIE's Canterbury guidance defines them.MBIE, Repairing and rebuilding houses affected by the Canterbury earthquakes, Part A, Version 3 (December 2012) · as at 15 September 2026Read it at the sourceRead the guideSpecific engineering designDesign where the design or design method is non-standard, outside the Acceptable Solution or Verification Method. It is usually done by a Chartered Professional Engineer.MBIE, The guide for Canterbury builders: Below-floor work, April 2013 · as at 15 September 2026Read the guideDamp-proof membrane (DPM)A membrane, usually polyethylene sheet, laid under a slab to stop moisture vapour rising from the soil into the concrete and the building interior.BRANZ Appraisals 964 and 1054; MBIE, Repairing and rebuilding houses affected by the Canterbury earthquakes, Part A, Version 3, Appendix A4.3.2; Firth, RibRaft Technical Manual (October 2024), Section 2 clause 3.6 · as at 15 September 2026Read the guide